CHEMFORT BAG ADAPTOR (SPIKE ADAPTER) BOX OF 80

Login to view prices

SKU:
MG-245251
Brand:
MG-245251
Chemfort® provides a new level of performance with no known incompatabilities with hazardous drug solvents, enhanced design and usability, and upgraded materials.
The Chemfort® Bag Adaptor SP connects to IV bags and other containers with a proximal spike connector, turning them into closed connections.
The Bag Adaptor SP does not require priming and its tail is opaque, enabling visual confirmation when spiking an IV set. In addition, the Bag Adaptor SP does not have a twist-off spike port or a pinch clamp, which requires fewer handling steps.
The Bag Adaptor SP enables simple dilution of the drug, and a safe drug transfer from a syringe to the IV container simply by clicking a Syringe Adaptor (SA) / Syringe Adaptor Lock (SAL) to the Bag Adaptor SP’s side port. The Chemfort® septa can be pierced up to 10 times, preventing drug leakage and contamination
[Product-availability]
Description
Offering a complete portfolio of products to fit any handling protocol, Chemfort™ helps to protect you at all stages from preparation to administration, and has no known incompatibilities with hazardous drug solvents. Cytotoxic drugs have been in use in oncology practice for decades. Most of them are administered intravenously and require reconstitution, dilution and transfer to IV bags or directly to the patient by syringe injection. Cytotoxic agents, by nature, are harmful to cancerous cells, yet they also damage healthy cells and tissues. Therefore, pharmacists and nurses who are involved in preparation and administration of chemotherapy as part of their work practice, should take precautions to eliminate or reduce exposure as much as possible. Chemfort™ is a premium closed membrane to membrane system transfer device (CSTD) that incorporates all of Tevadaptor’s demonstrated advantages while offering upgraded materials and improved usability. Drug containment is accomplished by the TOXI-GUARD® air cleaning system, which contains a 100% activated carbon drug binding matrix and 0.2 μm hydrophobic and oleophobic membrane. TOXI-GUARD® air cleaning system is also a sterile barrier helping to prevent micro-organisms and particles from entering the system. With an improved design and raw material upgrades, Chemfort™ CSTD delivers a new level of efficiency, performance and ease of use. Chemfort™ has been scientifically proven to help protect healthcare professionals when handling antineoplastic and other hazardous drugs.

CHEMFORT BAG ADAPTOR (SPIKE ADAPTER) BOX OF 80

Login to view prices

Chemfort® provides a new level of performance with no known incompatabilities with hazardous drug solvents, enhanced design and usability, and upgraded materials.
The Chemfort® Bag Adaptor SP connects to IV bags and other containers with a proximal spike connector, turning them into closed connections.
The Bag Adaptor SP does not require priming and its tail is opaque, enabling visual confirmation when spiking an IV set. In addition, the Bag Adaptor SP does not have a twist-off spike port or a pinch clamp, which requires fewer handling steps.
The Bag Adaptor SP enables simple dilution of the drug, and a safe drug transfer from a syringe to the IV container simply by clicking a Syringe Adaptor (SA) / Syringe Adaptor Lock (SAL) to the Bag Adaptor SP’s side port. The Chemfort® septa can be pierced up to 10 times, preventing drug leakage and contamination

Delivery within 1-5 working days (90% of orders will be received next working day)

Chemfort® provides a new level of performance with no known incompatabilities with hazardous drug solvents, enhanced design and usability, and upgraded materials.
The Chemfort® Bag Adaptor SP connects to IV bags and other containers with a proximal spike connector, turning them into closed connections.
The Bag Adaptor SP does not require priming and its tail is opaque, enabling visual confirmation when spiking an IV set. In addition, the Bag Adaptor SP does not have a twist-off spike port or a pinch clamp, which requires fewer handling steps.
The Bag Adaptor SP enables simple dilution of the drug, and a safe drug transfer from a syringe to the IV container simply by clicking a Syringe Adaptor (SA) / Syringe Adaptor Lock (SAL) to the Bag Adaptor SP’s side port. The Chemfort® septa can be pierced up to 10 times, preventing drug leakage and contamination
SKU: MG-245251 Categories: , Brand:

Description

Offering a complete portfolio of products to fit any handling protocol, Chemfort™ helps
to protect you at all stages from preparation to administration, and has no known
incompatibilities with hazardous drug solvents.

Cytotoxic drugs have been in use in oncology practice for decades. Most of them are administered intravenously and require reconstitution, dilution and transfer to IV bags or directly to the patient by syringe injection. Cytotoxic agents, by nature, are harmful to cancerous cells, yet they also damage healthy cells and tissues. Therefore, pharmacists and nurses who are involved in preparation and administration of chemotherapy as part of their work practice, should take precautions to eliminate or reduce exposure as much as possible. Chemfort™ is a premium closed membrane to membrane system transfer device (CSTD) that incorporates all of Tevadaptor’s demonstrated advantages while offering upgraded materials and improved usability.
Drug containment is accomplished by the TOXI-GUARD® air cleaning system, which contains a 100% activated carbon drug binding matrix and 0.2 μm hydrophobic and oleophobic membrane. TOXI-GUARD® air cleaning system is also a sterile barrier helping to prevent micro-organisms and particles from entering the system. With an improved design and raw material upgrades, Chemfort™ CSTD delivers a new level of efficiency, performance and ease of use. Chemfort™ has been scientifically proven to help protect healthcare professionals when handling antineoplastic and other hazardous
drugs.

Related Products